The data collection workstation is mainly used to automatically collect photos, videos, audio, logs, GPS tracks, and other data files on large-scale data collection devices such as body camera and USB flash drives, as well as data storage devices. It supports storage media access in the USB flash drive mode and internal storage mode, and achieves unattended data automatic collection, device charging, remote data query and other features.

  • This product can connect 20 body camera recorders at once to collect data simultaneously.
  • This product can charge the body camera while collecting data. The full load charging current can reach 5V 1.0-1.5A, and can charge 20 body camera simultaneously.
  • The collection rate of this product (20 body camera loaded) can reach a transmission rate of 3.8-8MB/s.
  • This product uses an industrial grade motherboard, which can be competent for 7 * 24 hours of uninterrupted work.
  • This product adopts capacitive touch technology, which is accurate and sensitive to touch.

Product parameters

System version Win10 64 bit system
Screen size 19 inchesTFT-LCD
Screen resolution 1280*800
CPU type I5 double core, 1.7GHz
System memory Standard configuration 4G DDR3
System disk Standard configuration 60G SSD
Storage capacity Standard configuration 1*4T 3.5 hard disk
3.5 inch hard disk drawer 8
IO interface 2*USB1*RJ45 Network20*Mini/Type-C USB
Sound 2*8Ω 3w Mini speaker
Acquisition speed Full load acquisition speed of 20 slots 3.8~8MB/S
Charging current Full load charging current for 20 slots 1.0~1.5A
Power 450W industrial grade switching power supply
Protection function OCP Overcurrent protection, OVP Overvoltage protection, OPP Overpower protection, SCP Short circuit protection,

Lightning protection

Attached accessories 1.8m national standard power line
Overall size (length*wide*Thick) 490×380×1569 mm
Net weight 39kg; Gross weight: 44kg
Operating temperature -10℃60℃
Operating humidity 10%90%
Storage temperature -20℃70℃
Storage humidity 10%90%

Product Features

No. Item Technical Specifications
1 Data interface Provide the HTTP protocol, for acquired data reading, writing, querying, and playing

2

Body camera access

registration

When the body camera is connected to the data collection workstation, the data collection workstation can obtain the camera ID and user ID from the body camera to verify whether the body camera have been associated and configured. If not, the administrator password verification should pop up, and the configuration can be associated to complete registration.
3 Automatic data collection The data collection workstation can automatically collect data such as video, audio, photos, and logs files from registered body camera, verify the consistency between the data collected by the data collection workstation and the original data stored by the body camera, and ensure that the collected data can be browsed normally.
4 Data browsing The data collection workstation can browse the collected video, audio, photos, logs, and other data.
5 Video playback Support for playback 3840 × 2160 resolution video 4K HD, supporting playback of videos with file encoding formats of H.264, H.265 (HEVC), and MPEG-4.
6 Data retrieval The data collection workstation can retrieve the collected video, audio, photos, logs, and other data based on one or more conditions such as the camera ID, user ID, record time, file type, and key tag files of the body camera.
7 Data reporting The data collection workstation can automatically upload video, audio, photos, logs, and other data to the management server, and can set the automatic upload time.
8 Data clearing The data collection workstation can automatically or manually clear the internal data of the body camera that has completed data uploading.
9 Automatic

delete the collected data

The data collection workstation can automatically delete data that exceeds the storage period, and the marked key files are not automatically deleted.
10 Body camera

timing

The data collection workstation can automatically correct the time of the accessed body camera, with the time accurate to the second.
11 Body camera charging The data collection workstation can automatically charge and display the charging status of the accessed body camera and can simultaneously charge multiple accessed body camera.

12

Acquisition status display The data collection workstation can display the information of each connected body camera (include serial ID, user ID, charging power, data collection progress, collection completion time, etc.) and the total storage capacity, remaining capacity, slot port status and other information of the collection workstation. For the slot that are not connected to the body camera, the slot status is displayed as idle.
13 Priority acquisition The data collection workstation has a priority slot. When this slot is connected to the body camera, data collection from other slot can be suspended and data collection from this slot can be prioritized. After data collection from the priority slot is completed, collection from other slot can be automatically resumed.

14

Data integrity

  1. During the data collection process, the user can select any connected body camera to cancel its data export, or manually pull it out. The data stored in the body camera and the collection workstation will not be lost.
  2. In the event of power failure, restart, crash, or accidental disconnection of the body camera at the data collection workstation, the stored data and configuration information in the body camera and collection workstation are not lost, and data collection can be automatically performed from the breakpoint after the next normal startup and connection.
15 Operation Log The data collection workstation can automatically log its own operation status and all operations, including on/off, user login and operation, access/removal of the body camera, data collection of the body camera time, and the time of fault occurrence/recovery.

16

Fault alarm

When abnormal conditions such as network interruption and storage overflow occur at the collection workstation, an audible alarm will be issued within 3 seconds. The sound pressure of the alarm indication is between 65dB-95dB, and the duration is not less than 5 minutes. During the alarm period, the audible alarm indication can be revoked through manual intervention. When a new alarm occurs, the audible alarm indication can be issued again, and the audible alarm indication can be automatically eliminated after the fault is completely restored.
17 File format

conversion

The data collection workstation can convert and output video, audio, or photo files to a new file format for network preview.
18 Key File Tags By the workstation software, the files that are manually determined as “key files” can be marked during the data browsing process and distinguished from the key marked files of the body camera. The key files can be marked and unmarked.
19 Data download Data such as video, audio, photos, and logs on the collection workstation can be downloaded and saved by the workstation software.
20 Data statistics By the workstation software, statistics can be made on stored video, audio, photos, logs, and other data based on one or more conditions such as the workstation ID, camera ID, username, user ID, company name, company ID, record time, file type, file tag, and reports or charts can be automatically generated.
21 Software

upgrade

The collection workstation can be upgraded remotely through the management server when connected to the network.
22 Timing of

collection workstation

When the collection workstation is connected to the network, the collection workstation can calibrate the time through the management server, and synchronize the time of the local computer with the time of the server.
23 User

permission management

The data collection workstation can be set with operation permissions, and unauthorized users cannot operate on the collection workstation. The operation permissions of authorized users have a hierarchical management mechanism.
24 Collection software login security The collection software has a user identity authentication mechanism, and the user login using a username and password.
The collection software has a login failure lock feature, which enables to lock the

account after the login failure exceeds the set number of times. The number of login failures and the length of the lock period can be set.

The collection software login password has complexity requirements, with a password length of at least 6 digits, and the password cannot be consecutive digits or the same number.
25 Voice

Announcements

When the body camera is connected to the collection workstation and the collection is completed, there is a voice prompt to broadcast.
26 Automatic

switching of storage space

The collection workstation supports multiple hard disk storage spaces. When one hard disk storage space is full, it automatically switches to the next storage space.
27 Working noise The working noise of the data collection workstation under normal working conditions shall not be greater than 60dB.